What was found
CRACK FOUND EMANATING FROM FASTENER OPPOSITE FITTING LATCH AT THE R1 DOOR BEAR STRAP BETWEEN BS 291.5 & 294.5, S8-9R. LENGTH OF CRACK 1.339'. PERFORMED CUT OUT AT BEARSTRAP IAW SRM 53-10-01-2R-6, REPAIR 6. STEP 4-C. FABRICATED REPAIR IAW SRM 53-10-01-2R-6, REPAIR-6, PROCEDURE 4, STEP E-1. TABLE 201. INSTALLED COUNTERSINK REPAIR WASHERS. COMPLETED INSTALATION OF DOUBLER AND TRIPLER IAW SRM 53-10-01-2R-6 REPAIR 6.