What was found
SMALL ANGLE CRACKED AT AFT KEEL BEAM LOWER BS 727 AND LBL 21. CRACK CONFIRMED IAW NDTM PART 6 ;51-00-00 PROCEDURE 23. CRACK LENGTH: 0.669'. REMOVED SMALL ANGLE AT AFT KEEL BEAM IAW SRM 51-40-02-OG-0. FABRICATEA NEW ANGLE IAW DWG 149A7692. LOCATED AND DRILLED THE NEW ANGLE IAW SRM 51-10-02-0G-0. TREATED AND PRIMED IAW AMM-51-21-72-370-801. ACCOMPLISHED ANGLE INSTALLATION AT AFT KEEL BEAM LOWER STA. 727 AND LBL21 IAW DWG 149A7692 AND BAC 5602.