What was found
DOT 07-186 FWD PIT FLOOR PANEL 120DF CORRODED ; / [01] DAMAGE FOUND OUT OF LIMITS DUE DAMAGE LENGTH IS MORE THAN 20 INCHES. IAW SRM 53-00-53-1A-1; FIG 202; [02] IDENTIFIED MATERIAL FOR PNL 120DF AS 2024 T3 -071 60W A TAG A3994 IAW 25-52-01-201-801;; [03] VERIFIED STEP 1 AND 2; [04] FABRICATED FLOOR PNL 120DF IAW AMM 25-52-01-839-001; [05] VERIFIED STEP 4; [06] VERIFIED STEP 4 AND OK TO TREAT AND PRIME; [07] TREATED AND PRIMED FL PNL 120DF IAW AMM 51-21-41-370-801 AMM 51-21-41-370-802 AND AMM 51-21-72-370-804; [08] VERIFIED. STEP 7; [09] COMPLIED WITH; [10] VERIFIED STEP 9; [11] VERIFIED STEP 9 AND AUDITED