What was found
CORROSION ON B.S. 259 LATERAL BEAM L.B.L. 10 - R.B.L. 10; W.L. 207.54. REMOVED CORROSION ON STA 259 LATERAL BEAM LBL 10- RBL 10; WL 207.54. AREA BLENDED IS 22' BY 1.3' ON UPPER SURFACE PER SRM 51-10-02-0G-0. ACCOMPLISHED UT INSPECTION IAW NDTM D6-37239 PART 4 51-00-00 PROC 2. LOWEST REMAINING THICKNESS .088. TOOL I.D. E650 ATS 2341. ACCOMPLISHED HFEC INSPECTION IAW NDTM D6-37239 PART 6 51-00-00 PROC 16 AND 53-30-00 PROC 3. ACCOMPLISHED HFEC INSPECTION IAW NDTM D6-37239 PART 6 51-00-00 PROC 23. NO CRACKS FOUND. REPAIRED DAMAGE PER EA 21-153-03707.