What was found
LT A/C BAY, BS 663, LBL 9.5; LOWER CHORD IS CRACKED. REMOVED DAMAGED SECTION IAW SRM 57-10-10-2R-5. REPLACEMENT ANGLE FABRICATED & -2 SPLICE ANGLE FABRICATED IAW SRM 57-10-10-2R-5. PERFORMED DETAILED INSP OF REPAIR AREA AND UNDERLYING STRUCTURE, NO DEFECTS NOTED IAW SRM 57-10-10-2R-5. COMPLETED FABRICATION OF ALL REPAIRS & PERFORMED INSURANCE CUT IAW SRM 57-10-10-2R-5. TREATED & PRIMED REPAIR & BARE SURFACES IN REPAIR AREA IAW SRM 57-10-10-2R-5. INSTALLED REPAIR ANGLES IAW SRM 57-10-2R-5. HFEC IAW NDT PART 6; 51-00-00 PROC 23 & 16. NO DEDECTS NOTED. APPLIED CAP SEAL TO FUEL TANK FASTENERS IAW SRM 57-10-10-2R-5. ACCOMPLISHED FUEL LEAK CHECK OF THE REPAIR AREA IAW AMM 28-11-00-400-801. NO LEAKS NOTED.