What was found
R/H BS 663 UPPER VAPOR BARRIER ATTACH ANGLE CRACKED AT RBL8 WL 167.68 ; / [01] UPDATED MEASUREMENT TABLE; [02] VALIDATED SRM 57-10-10-1A-2 ALLOWABLE DAMAGE TO BE CORRECT REFERENCE. FOUND CRACK AT BS 663 RBL 8 WL 167.68 OUT OF LIMITS PER SRM 57-10-10-1A-2 ALLOWABLE DAMAGE 2 PART WILL BE REMOVED AND REPLACED ON FAULT # TTG8Q009NVP2 NO FURTHER ACTION REQUIRED ON THIS CARD; [03] VERIFIED CRACKED ANGLE AT BS663 RBL8 WL167.68 WILL BE ADDRESSED ON TTG8Q009NVP2