What was found
AFT CARGO DOOR THRESHOLD WEB IS CORRODED. REMOVED WEB, & REMOVED DAMAGE IAW SRM 53-60-15-1A-1, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1. DRILLED A NEW AFT CARGO DOOR THRESHOLD WEB IAW SRM 51-40-05. REMOVED AND REPLACED THE AFT CARGO DOOR THRESHOLD WEB IAW SRM 51-40-02.