What was found
CORRODED INSERTS (10 EA) ON PASSENGER CABIN FLOOR PANEL 242UF. FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4F. REMOVED DAMAGED PLIES AND CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARA 3A-F. APPLIED POTTING COMPOUND IAW SRM 53-00-50-2R-1 PARA 3G. INSTALLED REPAIR PLIES IAW SRM 53-00-50-2R-1 PARA 3.K.(1) AND L.(1). INSTALLED ALL REMOVED INSERTS, INSTALLED ONE DRAIN FITTING IAW SRM 53-00-50-2R-1 PARA 3.M.(1) AND N, DRAWING 147A5810 SHEET 95 AND BAC5010 PARA 8.2.19 FIGURE 2.