What was found
CORRODED INSERTS ON PASSENGER CABIN FLOOR PANEL 242WF ; / [01] FOUND ADDITIONAL DAMAGE ON LOWER SURFACE OF PANEL.<BR>DUE TO THE EXTENT OF DAMAGE; REPLACED FLOOR PANEL 242WF WITH NEW PANEL IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-26 ITEM 195.; [02] FINAL INSPECTION. PANEL REPLACED. JOB COMPLETE PER SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-26 ITEM 195.