What was found
CORROSION- BS727 LBL9 FLOOR SUPPORT TO FWD BLKHD SUPPORT CORRODED, NO ALLOWABLE DAMAGE LIMITS ON SRM. REMOVED FLOOR SUPPORT IAW SRM 51-40-02-0G-0. FABRICATED, LOCATED, AND DRILLED THE NEW FLOOR SUPPORT IAW SRM 51-40-05-0G-0, AND DWG# 144A2600. APPLIED A CHEMICAL CONVERSION COATING IAW SOPM 20-43-03. PRIMED THE NEW ACB BS 727 LBL 9 FLOOR SUPPORT TRACK TO FWD BLKHD SUPPORT IAW SOPM 20-44-04 . INSTALLED THE NEW FLOOR SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 146A2600.