What was found
CORROSION ON BS 727C, LBL 7, WL 152 ATTACH ANGLE. EVALUATED CORROSION DAMAGE ON ATTACH ANGLE, FOUND TO BE OUT OF LIMITS IAW SRM 51-10-02-02-0G-0. REMOVED ATTACH ANGLE IAW SRM 51-40-02. FABRICATED, LOCATED, AND DRILLED A NEW ATTACH ANGLE IAW SRM 51-40-05, AND AND APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01 AND DWG 146A1320 REV A. PRIMED ANGLE IAW SOPM 20-41-02, AND DWG 146A1320 REV A. INSTALLED ATTACH ANGLE IAW SRM 51-40-02-0G-0, AND DWG 146A7810 REV A.