What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT RBL 24 BS 400+10. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 PARAG. 4.A.(2). DETAIL D. REMOVED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0. FABRICATED LOCATED AND DRILLED A NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0, AND DWG 143A7500. APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01-0G-0. PRIMED FCB FLOOR TO SIDE WALL SUPPORT ANGLE IAW SOPM 20-41-02. INSTALLED ON TASK CARD TTG8Q004E4G0.