What was found
BS 663 VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT RBL 8, WL 160. EVALUATED CRACKED ATTACH ANGLE & FOUND TO BE OUT OF LIMITS. CRACK LENGTH 1.2'' IAW SRM 57-10-10-1A-2. ACCOMPLISHED CUT OUT OF ATTACH ANGLE IAW SRM 57-10-10-2R-5 REPAIR 5 PART 4B. HFEC INSPECTED ALL OPEN HOLES IN REPAIR AREA AND TRIMMED EDGE OF DAMAGE CUTOUT PER NDT PART 6 51-00-00 PROCEDURES 16 AND 23. NO CRACKS FOUND. LOCATED AND DRILLED REPAIR ANGLE SECTION AND REPAIR SPLICE IAW SRM 57-10-10-2R-5. INSTALLED REPAIR PARTS IAW SRM 57-10-10-2R-5. PPLIED ELECTRICAL BONDING CHECK AT REPAIR AREA IAW SRM 57-10-10-2R-5. APPLIED FILLET SEAL AT REPAIR AREA IAW 57-10-10-2R-5.