What was found
CRACKED FLOOR SUPPORT AT STA 344+9; LBL 1; WL 208. ; / [01] REMOVED INTERCOSTAL SUPPORT AT FLOOR STRUCTURE BETWEEN BS 344 TO BS 360 WL 208 LBL 1 SRM 51-40-02; [02] LOCATED AND DRILLED NEW FLOOR SUPPORT INTERCOSTAL P/N 141A5410U23 LOT #1472062-1 BETWEEN BS 344 TO BS 360 BL 0 PER SRM 51-40-05 AND DWG 141A5400 OK TO INSTALL PART; [03] VERIFIED CORRECTIVE ACTION 2; [04] INSTALLED FLOOR SUPPORT INTERCOSTAL AT BS 344 TO BS 360 BL 0 WL 208 PER SRM 51-40-02 AND DWG 141A5400; [05] VERIFIED CORRECTIVE ACTION 4; [06] VERIFIED CARD COMPLETE