What was found
SUPPLEMENTAL INFORMATION: FWD CARGO BAY GUSSET IS CRACKED AT BS 500D COMMON TO STR 19R ; / [01] EVALUATED GUSSET; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED EVALUATED GUSSET; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] REMOVED FWD CARGO BAY GUSSET BS 500D COMMON TO STR 19R; PER SRM 51-40-02-0G-0; [04] LOCATED AND DRILLED NEW GUSSET FWD CARGO BAY R/H 500D STR 19R PER SRM 51-40-05-0G-0 AND DWG 143A7902. <BR><BR>OK TO INSTALL.; [05] VERIFIED CORRECTIVE ACTION 4; OK TO INSTALL GIVEN.; [06] BEGAN INSTALLING FASTENER COMMON BS 500D TO STR 19R GASSET PER 51-40-02-0G-0 AND DWG 143A7902; [07] INSTALLED FWD CARGO BAY GUSSET AT BS500D COMMON TO STRINGER 19R PER SRM 51-40-05-0G-0 AND DRAWING 143A7902; [08] SHOULD READ SRM 51-40-02-0G-0; [09] CERTIFIED STEPS 7 AND 8; [10] VERIFIED INSTALLATION OF THE BS500D STR19R GUSSET PER SRM 51-40-05-0G AND DWG 143A7902; [11] WORKSCOPE COMPLETE