What was found
SUPPLEMENTAL INFORMATION: FWD CARGO BAY GUSSET IS CRACKED AT BS 500D COMMON TO STR 23L ; / [01] CORRECT LOCATION OF CRACKED GUSSET IS BS 500D STRINGER 19 L/H; [02] EVALUATED GUSSET; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] VERIFIED EVALUATED GUSSET; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0 AND CORRECT LOCATION OF CRACKED GUSSET IS BS 500D STRINGER 19 L/H; [04] LOCATED AND DRILLED NEW GUSSET FWD CARGO BAY L/H 500D STR 19L PER SRM 51-40-05-0G-0 AND DWG 143A7902. <BR><BR>OK TO INSTALL.; [05] VERIFIED CORRECTIVE ACTION 4; OK TO INSTALL GIVEN.; [06] INSTALLED NEW GUSSET FWD CARGO BAY L/H BS 500D STR 19L; PER SRM 51-40-02-0G-0 AND DWG 143A7902.; [07] VERIFIED CORRECTIVE ACTION 6.; [08] VERIFIED ALL STEPS COMPLETE.