What was found
SUPPLEMENTAL INFORMATION: FWD CARGO BAY GUSSET IS CRACKED AT BS500D COMMON TO STR 21R ; / [01] EVALUATED GUSSET; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED EVALUATED GUSSET; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] REMOVED FWD CARGO BAY GUSSET BS 500D COMMON TO STR 21R; PER SRM 51-40-02-0G-0; [04] RECEIVED NEW GUSSET FROM OSS; MATERIAL USED 7075T62 0.040' CLAD LOT# 1468510-2 R0 #848184-SWA. LOCATED AND DRILLED GUSSET PER SRM 51-40-05-0G-0; AND DWG 143A7902; [05] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON FWD CARGO BAY GUSSET BS 500D COMMON TO STR 21R PER AMM 51-21-41-370-802 AND 51-21-72-370-804.; [06] OK TO INSTALL; [07] VERIFIED NEW GUSSET FABRICATED AND DRILLED UP PER SRM 51-40-05-0G-0 AND DWG 143A7902. <BR>VERIFIED CHEMICAL CONVERSION COATING AND PRIMER ON APPLIED ON NEW FWD CARGO BAY GUSSET PER AMM 51-21-41-370-802 AND 51-21-72-370-804.<BR>OKAY TO INSTALL NEW GUSSET.; [08] INSTALLED NEW FWD CARGO BAY GUSSET BS 500D TO STR 21R; IAW SRM 51-40-02-0G-0 DWG 143A7902; [09] VERIFIED CORRECTIVE ACTIONS STEP 8.