What was found
SUPPLEMENTAL INFORMATION: CRACK FLOOR BEAM REINFORCEMENT ANGLE RBL52 BS 294.5 AT FWD GALLEY AREA ; 2021-544646 / [01] TOOL USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 22-JAN-22; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 22-JAN-22.; [02] FABRICATED REINFORCEMENT ANGLE AND FASTENERS ON FLOOR BEAM BS 294.5 AT FWD GALLEY AREA B737-700 SRM 51-40-02 AND SRM 51-10-02 STEP 9; DWG 141A5502 SHEET 15 REV:-; [03] REPLACED REINFORCEMENT ANGLE AND FASTENERS ON FLOOR BEAM BS 294.5 RBL 30 TO RBL 53 AT FWD GALLEY AREA B737-700 SRM 51-40-02 AND SRM 51-10-02 STEP 9; DWG 141A5502 SHEET 15 REV:-; [04] CORRECTED STEP 3:<BR>REPLACED REINFORCEMENT ANGLE AND FASTENERS ON FLOOR BEAM BS 294.5 RBL 30 TO RBL 53 AT FWD GALLEY AREA B737-700 SRM 51-40-02 AND SRM 51-10-02 STEP 9; DWG 141A5502 SHEET 15 REV:- SEE INDIVIDUAL SIGN OFF BELOW; [05] CORRECTED STEP 3: <BR>REPLACED REINFORCEMENT ANGLE AND FASTENERS ON FLOOR BEAM BS 294.5 RBL 30 TO RBL 53 AT FWD GALLEY AREA B737-700 SRM 51-40-02 AND SRM 51-10-02 STEP 9; DWG 141A5502 SHEET 15 REV:- RII; SEE INDIVIDUAL SIGNOFF BELOW.