What was found
ELONGATED HOLE DOOR CUTOUT WEB UPPER AREA LOCATED BETWEEN BS442 TO BS 490 AT FWD CARGO COMPARTMENT. REPLACED DOOR CUTOUT WEB UPPER AREA LOCATED FASTENERS IAW SRM 51-40-02 AND SRM 51-10-02 AND DWG 143A0081 SHEET 38 REV. B. REPLACED DOOR CUTOUT WEB UPPER IAW SRM 51-40-02 AND SRM 51-10-02 AND DWG 143A0081 SHEET 38 REV B.