What was found
SUPPLEMENTAL INFORMATION: CABIN FLOOR INTERCOSTAL BS 344-360 BL 0 CRACKED BY FWD SCREW HOLE. 8-54 ; / [01] INSTALLED EWIS PROTECTION DURING MAINTENANCE IN THE AREA OF WORK IN IAW AMM 20-60-07-913-801; [02] REMOVED INTERCOSTAL AT MAIN CABIN FROM BS 344 TO 360 BL 0 IN REF B737-700 SRM 51-40-02-0G-0; [03] LOCATED AND DRILLED NEW INTERCOSTAL AT CABIN FLOOR BS 344 TO 360 BL 0 IN IAW SRM 51-40-02-0G-0 P/N: 141A5410U23; [04] VERIFIED STEPS 1 ;2; AND 3 ;OK TO TREAT PRIME HOLES; [05] TREATED WITH ALODINE AND PRIMED ALL FASTENERS HOLES IN IAW SRM 51-20-01-0G-0 AND 51-21-72-370-804; [06] VERIFIED STEP 5 AND OK TO INSTALL NEW INTERCOSTAL; [07] INSTALLED NEW INTERCOSTAL AT CABIN FLOOR FROM BS 344 TO 360 BL-0 IN IAW SRM 51-40-02-0G-0 AND DWG # 141A5400; [08] REMOVED EWIS PROTECTION OF AREA IN REF IN IAW AMM 20-60-07-913-801; [09] REMOVED AND REPLACED INTERCOSTAL AT CABIN FLOOR FROM BS 344-360 BL 0 IN IAW SRM 51-40-02-0G-0 AND DWG# 141A5400; [10] RII VERIFIED STEPS 8 AND 9