What was found
FLOOR SUPPORT CRACKED BS 312+10 TO 312+11 BL 0 WL 208 ; / [01] CORRECTION TO FAULT: FLOOR SUPPORT CRACKED BS 312+10 TO 312+11 LBL45 WL 208; [02] REMOVED DAMAGE FLOOR SUPPORT BS 312-328 LBL45 WL 208 IAW SRM 51-40-02-0G-0.; [03] CERTIFIED REMOVED OF DAMAGE FLOOR SUPPORT; [04] LOCATED AND DRILLED NEW FLOOR SUPPORT BS321-328 LBL45 WL 208 IAW SRM 51-40-05-0G-0; OK TO INSTALL.; [05] CERTIFIED LOCATE AND DRILL OF NEW FLOOR SUPPORT; [06] VERIFIED LOCATED AND DRILLED NEW FLOOR SUPPORT BS321-328 LBL45 WL 208 IAW SRM 51-40-05-0G-0; OK TO INSTALL.; [07] INSTALLED NEW FLOOR SUPPORT AT BS 312-328 LBL45 WL 208 IAW SRM 51-40-02-0G-0 AND DWG 141A5400; [08] CERTIFIED INSTALLATION OF FLOOR SUPPORT AT BS 312-328 LBL45 WL 208; [09]