What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS380 TO BS400 AND RBL10 FWD GALLEY AND LAV ; 2021-536648 / [01] TOOL USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 22-JAN-22; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 22-JAN-22.; [02] REPLACED WEB INTERCOSTAL LOCATED BTW BS380 TO BS400 AND RBL10 FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9; AND DWG NO. 143A5400; SHEET 38; RE. A. SEE INDIVIDUAL SINGOFFS BELOW.; [03] REPLACED WEB INTERCOSTAL LOCATED BTW BS380 TO BS400 AND RBL10 FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9; AND DWG NO. 143A5400; SHEET 38; RE. A. SEE INDIVIDUAL SING-OFFS BELOW.