What was found
CORRSION FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT BS 440+17; BS 460+7; BS 480+3;+12; BS 500+9; +14; BS 500A+10; BS 500B+14;+18 LBL 24 ; / [01] EVALUATED CORROSION AT ALL LOCATION; FOUND DEEPEST LOCATION TO BE AT BS 440+17 LBL 24 WL 156. FOUND 0.015 REMOVED FROM ORIG 0.040 IN 1'X1' AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2678 S/N UNKNOWN; [02] VERIFIED EVALUATED CORROSION AT ALL LOCATION; FOUND DEEPEST LOCATION TO BE AT BS 440+17 LBL 24 WL 156. FOUND 0.015 REMOVED FROM ORIG 0.040 IN 1'X1' AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2678 S/N UNKNOWN; [03] BEGAN LOCATING AND DRILLING NEW FCB FLOOR TO SIDEWALL SUPPORT BS396 - BS500D; LBL25; WL156. PER DWG143A7500 AND SRM 51-40-05-0G-0.; [04] LOCATED AND DRILLED NEW FCB L/H FLOOR TO SIDEWALL SUPPORT BS396 - BS500D; LBL25; WL156. PER DWG 143A7500 AND SRM 51-40-05-0G-0; [05] VERIFIED CORRECTIVE ACTIONS STEP 4.; [06] VERIFIED COMPLETED.