As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION; AFT CARGO FLOOR PANEL SUPPORT T-ANGLE UPPER FLANGE; BS 794.5; RBL 18. FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT IAW SRM 51-10-02-0G-0. REMOVED FLOOR PANEL SUPPORT T-ANGLE IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED ACB FLOOR PANEL SUPPORT ANGLE UPPER FLANGE IAW SRM 51-40-05-0G-0 AND DWG 146A7500. INSTALLED NEW FLOOR PANEL SUPPORT ANGLE IAW SRM 51-40-02-0G-0 AND DWG 146A7500.