What was found
E&E COMPARTMENT LOWER AUXILIARY SILL; S-23L FROM STA 294.5 TO STA 344 APPX. CORROSION NOTED ON OUTER CHORD (ANGLE). ; / [01] INSTALLED PROTECTION EWIS ON AREAS AT E/E COMPARTMENT LOWER AUX SILL S-23L FRONT STA 294.5 TO STA 344 AS PER REF B 737-700 AMM 20-60-07-913-801; [02] REMOVED EXFOLIATED OUTER CHORD ANGLE AT E&E COMPARTMENT LOWER AUXILIARY SILL AT S23L FROM STA 294.5 TO STA 344 APPX. IAW SRM 51-40-02-0G-0.; [03] (RII) VERIFIED STEPS #1 AND #2; [04] LOCATED AND DRILLED OUTER CHORD (ANGLE) AT E&E COMPARTMENT LOWER AUXILIARY SILL AT S23L FROM STA 294.5 TO STA 344 IAW B737-700 SRM 51-40-05-0G-0 AND DWG # 141A8240.