What was found
E&E COMPARTMENT LOWER AUXILIARY SILL BETWEEN S-21L AND-23L AT STA 320. FOUND CORROSION ON ANGLE. REMOVED EXFOLIATED ANGLE CHORD AT E&E COMPARTMENT LOWER AUXILIARY SILL; BETWEEN S21L AND S23L AT STA 320 APPX. IAW SRM 51-40-02-0G-0. REMOVED ANGLE CHORD AT E&E BAY LOWER SILL. FOUND OUT OF LIMITS IAW SRM 53-10-15-1A-1; 4.A. LOCATED AND DRILLED NEW ANGLE. FOUND OUT OF LIMITS IAW SRM 51-40-05-0G-0 AND DWG#141A8240. TREATED AND PRIMED DRILLED HOLES. INSTALLED NEW ANGLE IAWSRM 51-20-01-0G-0 AND DWG#141A8240.