What was found
CORROSION SPOTS ON CABIN FLOOR WEB AFT WET AREA B.S. 1006+9 L.BL. 40'. (51-002). REMOVED CORROSION AT AFT CABIN FLOOR WEB AT STA 1006+9 AND LBL 40' IAW SRM 53-70-51-1A-1-A00108. REMOVED SHEAR WEB CORROSION WAS EXFOLIATING WEB IS OUT OF LIMITS IAW 51-40-02-0G-0. LOCATED & DRILLED A NEW WEB IAW SRM 51-40-05-0G-0 AND DWG 147A5600. PARTIALLY INSTALLED FLOOR WEB IAW SRM 51-40-02-0G-0. COMPLETED INSTALLATION OF CABIN FLOOR WEB IAW SRM 51-40-02-0G-0 AND DWG 147A5600.