What was found
FWD CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT ANGLE CORROSION; LBL23; BS460+10; BS480+6; BS500-2 ; / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 460+10 LBL 23 WL 156. FOUND 0.015 TO BE REMOVED FROM ORIG 0.040 IN 1'X1' AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ID ATS 2678 S/N UNKNOWN; [02] VERIFIED CORRECTIVE ACTION 1.<BR><BR>OUT OF LIMITS.; [03] RECEIVED NEW FCB LH FLOOR TO SIDEWALL SUPPORT; LOCATED AND DRILLED; FCB LH FLOOR TO SIDEWALL; BS396-500D; IAW SRM 51-40-05-0G-0; DWG 143A7500.; [04] VERIFIED RECEIVED NEW FCB LH FLOOR TO SIDEWALL SUPPORT; LOCATED AND DRILLED; FCB LH FLOOR TO SIDEWALL; BS396-500D; IAW SRM 51-40-05-0G-0; DWG 143A7500.