What was found
FWD CARGO FLOOR STRUCTURE AFT BULKHEAD ANGLE AT STA 500I LBL 24- RBL24 HAS NUMEROUS AREAS OF SURFACE CORROSION. (MARKED) ; / [01] REMOVED CORROSION PER SRM 51-10-02. BLEND DEPTH IS .016 INCH. REMAINING MATERIAL THICKNESS IS .059 INCH AND IS OUT OF LIMITS PER SRM 53-30-08-1A-1.; [02] REMOVED AND INSTALLED NEW FWD CARGO FLOOR STRUCTURE AFT BULKHEAD ANGLE AT STA. 500I; LBL 24 TO RBL 24 .IAW SRM 51-40-02. SEE STEPS FOR INDIVIDUAL SIGN OFFS OF WORK PREFORMED.; [03] C/W