What was found
CABIN FLOOR BEAM HAS CORROSION AT B.S. 947.5; LBL 51'. AREA MARKED. ; / [01] BLENDED CORROSION PER SRM 51-40-02. DAMAGE REMOVAL ON CABIN FLOOR BEAM AT STA. 947.5; LBL 51' IS OUT OF LIMITS PER SRM 53-70-51-1A-1.; [02] VERIFIED BLENDED CORROSION PER SRM 51-40-02. DAMAGE REMOVAL ON CABIN FLOOR BEAM AT STA. 947.5; LBL 51' IS OUT OF LIMITS PER SRM 53-70-51-1A-1; [03] CUT AND REMOVED DAMAGED UPPER CHORD OF FLOOR BEAM AT STA 947.5 FROM RBL 59 TO LBL 59 PER SRM 53-70-51-2R-5; ALTERNATIVE 1.; [04] FABRICATED REPLACEMENT LEFT AND RIGHT UPPER T-CHORD SECTIONS; DE-BURRED REPAIR PARTS; TREATED AND PRIMED REPAIR PARTS; ALL IN ACCORDANCE WITH SRM 53-70-51-2R-5; ALTERNATIVE 1; AND EA 21-153-03565 WIP?S 1-3.;