What was found
FWD CARGO COMPARTMENT FLOOR STRUCTURE STA 500B TO 500C; RBL 24; WL 156 R/H Z-ANGLE HAS CORROSION. A224-12 ; / [01] REMOVED CORROSION IAW SRM 51-10-02 VERIFIED WITH 10X MAGNIFY ORIGINAL THICKNESS .040 MATERIAL REMOVED .007 REMAINING MATERIAL .033 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 TOOL NO. AAR 36644 DUE 20 AUG 22; [02] VERIFIED STEP 1 COMPLETE; [03] VERIFIED STEP 1; [04] WORK ACCOMPLISHED ON TASK CARD TTG8Q009UFWM; [05] VERIFIED STEP 4 IS COMPLETE; [06] VERIFIED