What was found
DOT 050-012 AFT CARGO COMPARTMENT L/H SIDE ZEE ANGLE STA 727F TO STA 727J LBL 20 WL 156 IS CORRODED ; / [01] BLENDED CORROSION ON LH ZEE ANGLE STA 727F-727J. FOUND STA 727G+10'-727J OUT OF LIMITS WITH ORIGINAL .040'; REMAINING .023'; LOSS OF .017' IAW SRM 53-00-53-1A-2 <BR>TOOL #36649 CAL. DUE: 12AUG22; [02] VERIFIED STEP COMPLETE; [03] VERIFIED STEPS 1 & 2.; [04] OK TO TREAT AND PRIME; [05] TREATED AND PRIMED ALL IN LIMITS BARE SURFACES IN AREA IAW SRM 53-00-53-1A-2; [06] VERIFIED STEP 5; [07] STEP 5 AND 6 C/W; [08] REPLACED DAMAGED SECTION OF Z ANGLE STA 727+ 10' TO STA 787 +10' ON W/O TTG8Q009USE7; [09] RESTORED CIC TO DISTURBED AREAS IAW SRM 53-00-53-1A-2; [10] VERIFIED STEPS 8 AND 9 ARE COMPLETE; [11] VERIFIED STEPS 8-9; [12] FAULT WAS RESOLVED ON FAULT CARD TTG8Q009USE7; [13] VERIFIED STEP 12. AUDIT COMPLETE