What was found
AFT CARGO COMP L/H BETWEEN STA 747 AND STA 847 ZEE CHANNEL UPPER SURFACE SEVERAL AREA WITH CORROSION. REMOVED CORROSION IAW SRM 51-10-02-0G-0-A00248. PERFORMED UT THICKNESS INSP. ON REWORKED AREA IAW NDT PART 4 51-00-00 PROC. 3. MIN THICKNESS .029'. ORIGINAL MATERIAL 0.040;MATERIAL LOSS 0.011 MATERIAL REMAINING 0.029, OUT OF LIMITS IAW SRM BCG D634A201. FABRICATED NEW ZEE CHANNEL FROM BS 747 TO 847 IAW SRM 53-60-53-01-2 AND DWG 146A7500. MEASUREMENTS INPUT ONLY; [09] STEP 7/8 VERIFIED; OK TO TREAT/PRIME; [10] TREATED AND PRIMED ZEE CHANNEL REF SRM 51-20-01-0G-0 AND AMM 51-21-72-370.