What was found
FOUND CORROSION & WORN AT L-1 DOOR CUTOUT FWD. FRAME LOWER HINGE BOX UPPER FITTING HOLE. PARTIAL REMOVED HINGE BOX AT L-1 DOOR CUTOUT FWD. FRAME LOWER. IAW SRM 51-40-02. INSTALLED EWIS PROTECTION AT L-1 DOOR CUTOUT FWD. LOWER HINGE BOX AREA DURING MAINT. IAW AMM 20-60-07-913-801. REMOVED INTERCOSTAL STR 13L AT L-1 DOOR CUTOUT FWD IAW SRM 51-40-02-0G-0; REMOVED INTERCOSTAL STR 13N-L AT L-1 DOOR CUTOUT FWD. AT L-1 DOOR CUTOUT FWD. LOCATED AND DRILLED NEW HOLES ON FWD FRAME LOWER HINGE BOX AT L-1 DOOR CUTOUT IAW SRM 51-40-05-0G-0; LOCATED AND DRILL ALL REMAINING NEW HOLE ON FWD FRAME LOWER HINGE BOX AT L-1 DOOR CUTOUT IAW SRM 51-40-05-0G-0 AND DWG 141A8180.