What was found
CORROSION ON TRACK AT AFT CARGO BAY BS727A; BS787+13 RBL13. ; / [01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS ON CARGO TRACK IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2 AND SRM 53-60-53-01-2 IDENTIFICATION 2; [02] REMOVED CORROSION ON AFT CARGO TRACK BAY B/S 727A RBL13 L: 1' W:0.800' DEPTH : 0.025' AND B/S 787+13 L:1.25' W:0.900' DEPTH:0.024' IAW SRM 51-10-02 PARAGRAPH 15 .<BR>EVALUATED REWORKED AREA ; ORIGINAL THICKNESS : 0.070' REMAINING THICKNESS : 0.045' AND FOUND OUT LIMITS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2 FIGURE 103 DETAIL 'G' TOOL USED CALIPER ID:ATS2501 DATE DUE:03/2022; [03] SEE CUST SYSTEM ID: TTG8Q009PQHW FOR PART REPLACEMENT; [04] VERIFIED CORRECTIVE ACTIONS 1;2 AND 3.