What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 AT LBL 47 AT FWD GALLEY AREA ; 2021-558159 / [01] REPLACED WEB-INTERCOSTAL AND FASTENERS LOCATED BTW BS 312 TO BS 328 AT LBL 47 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02 AND 51-10-02 ITEM 9 AND DRAWING 141A5400 REV-; [02] CORRECTED STEP 1 REPLACED WEB-INTERCOSTAL AND FASTENERS LOCATED BTW BS 312 TO BS 328 AT LBL 47 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02 AND 51-10-02 ITEM 9 AND DRAWING 141A5400 REV- SEE INDIVIDUAL SIGN OFFS BELOW.; [03] REPLACED WEB-INTERCOSTAL AND FASTENERS LOCATED BTW BS 312 TO BS 328 AT LBL 47 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02 AND 51-10-02 ITEM 9 AND DRAWING 141A5400 REV- SEE INDIVIDUAL SIGN OFFS BE