What was found
STR 25L SPLICE CRACKED BS 888. TRIMMED SPLICE AND APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01-0G-0 AND DWG 147A3288. NO ALLOWABLE DAMAGE FOR STRINGER SPLICE AT STR25L BS888 IAW SRM 53-00-03-1A-1. REMOVED CRACKED STRINGER SPLICE AT S25L, BS888 IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED STRINGER SPLICE BS 888 STR 25L IAW SRM 51-40-05 AND DWG 147A3288. APPLIED PRIMER AT NEW SPLICE IAW DWG 147A3288. INSTALLED SPLICE AT STR 25L BS 888 WL 166 IAW SRM 51-40-02 AND DWG 147A0060 ID: 0001 REV: A AND DWG 147A0060 ID: 0002 REV: -.