Service difficulty report · Floor Panel · Boeing

Difficulty date
April 27, 2017
Submitted
January 24, 2022
Operation
Air carrier
Make and model
Boeing
Aircraft time
40,562 hours, 23,779 cycles
Part
Floor Panel
Condition
Pulled
Location
Cabin
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFT CABIN FLOOR PANEL 241ADF HAS AN AREA OF PULLED STRANDS (MARKED) AND DAMAGED INSERTS. / REPAIRED MARKED AREA OF PULLED STRANDS AND REPLACED DAMAGED INSERTS ON AFT CABIN FLOOR PANEL 241ADF IAW SRM 53-00-50-2R-1. 56749U 02MAY17