What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 480+10; BS 480+14; BS 500+10; BS 500+14; BS 500A+6; BS 500A+10; BS 500A+14; BS 500B+1; BS 500B+14; BS 500C+7. REMOVED CORROSIONS FROM FCB L/H FLOOR TO SIDEWALL SUPPORT, ORIGINAL THICKNESS 0.040'BS 500A+10 L= 1.000' W= 0.400' D=0.002' ORIGINAL THICKNESS 0.040' FOUND TO BE OUTLIMITS IAW SRM 53-00-53-1A-2. CONVERSION COATING IAW SOPM 20-41-02. OK TO APPLY PRIMER. FABRICATED REPLACEMENT FLOOR SIDEWALL SUPPORT AND SPLICE SIDEPLATE IAW SRM 53-00-53-2R-5 AND DWG 143A7501 ID:0001 REV:B. APPLIED CHEMICAL CONVERSION COATING IAW SOPM 20-41-02.