What was found
CRACK ON FWD CARGO BAY FRAME TO INTERCOSTAL AT LBL 24 BS 400. THERE IS NO SRM ALLOWABLE DAMAGE FOR FWD CARGO BAY FRAME TO INTERCOSTAL AT L/H STR 24 BS 400. REMOVED FCB FRAME TO INTERCOSTAL CLIP AT LBL24 BS 400 IAW SRM 51-40-02-0G-0; REMOVED FCB INTERCOSTAL AT LBL 24 BS 400 - 420 IAW SRM 51-40-02-0G-0; [05] LOCATED AND DRILLED NEW FRAME TO INTERCOSTAL CLIP IAW SRM 51-40-05-0G-0 AND DWG 143A7502 REV : G; LOCATED AND DRILLED NEW CLIP PER SRM 51-40-05 AND DWG 143A7502. INSTALLED NEW CLIP TO INTERCOSTAL IAW SRM 51-40-02-0G-0 AND DWG 143A7505 REV : B.