What was found
CRACK ON FWD CARGO BAY FRAME TO INTERCOSTAL AT LBL 24 BS 500C+1. THERE IS NO SRM ALLOWABLE DAMAGE FOR FWD CARGO BAY FRAME TO INTERCOSTAL AT L/H STR 24 BS 500C+1. PART TO BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0; [02] REMOVED FCB FRAME TO INTERCOSTAL AT LBL24 BS 500C+1 IAW SRM 51-40-02-0G-0; [03] VERIFIED CORRECTIVE ACTION#1 AND #2; [04] LOCATED AND DRILLED NEW FCB FRAME TO INTERCOSTAL CLIP AT LBL24 BS 500C+1 IAW SRM 51-40-0G-0G-0 AND DWG 143A7502 REV:G; [05] VERIFIED LOCATED AND DRILLED NEW CLIP PER SRM 51-40-02 AND DWG 143A7502. INSTALLED INTERCOSTAL CLIP AT FCB LBL 24 BS 500C+1 IAW SRM 51-40-02 AND DWG 143A7505 ID: 0003 REV: A.