What was found
CORROSION AFT CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT BS 887 RBL 24 ; EVALUATED CORROSION AFT CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT. NOT FOUND ALLOWABLE DAMAGE LIMITS ON SRM. REMOVED AFT CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02. LOCATED AND DRILLED AT AFT CARGO FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05 AND DWG 146A7502 REV A AND DWG 147A7500 REV:B. INSTALLED AT AFT CARGO FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02 AND DWG 146A7502 REV A AND DWG 147A7500 REV B.