What was found
CORROSION ON SHIELD TO FRAME ATTACH FITTING BS767 RBL22. EVALUATED CORROSION. FRAME ATTACHED FITTING. CORROSION FOUND TO BE IN A 1'X 1' AREA, DEPTH 0.20' THERE IS NO SRM LIMIT FOR THE PART. PART FOUND TO BE OUT OF LIMITS. REMOVED FRAME ATTACHED FITTING. SRM 51-10-02, SRM 53-60-15-1A-1, & SRM 51-40-02. LOCATED & DRILLED ATTACH FITTING IAW DWG 146A0081 REV -, SRM 51-40-05-0G-0. INSTALLED NEW ATTACH FITTING IAW SRM 51-40-02-0G-0 AND DWG 146A8123; ID: 16; REV:-.