What was found
SUPPLEMENTAL INFORMATION: FAIRING 195CL HAS DELAMINATIONS OVER CORE AREA NEXT TO EDGEBAND OF PANEL SEE FAULT TTG8Q009PY4M. ; / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-40-70-0I-1 FIG 2 TABLE 2 ITEM 5. <BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-40-70-1A-1 PARA 4A(6). <BR>DAMAGE WILL BE REPAIRED IAW SRM 51-70-05-2R-1 PER SRM 53-40-70-2R-1 TABLE 201. <BR>REMOVED 4EA AREAS OF DELAMINATION OVER CORE; CLEANED REPAIR AREA IAW SRM 51-70-05-2R-1 PARA 4B.; [02] VALIDATED APPLICABILITY OF SRM 51-70-05-2R-1; [03] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2. OKAY TO PROCEED PER SRM 51-70-05-2R-1.; [04] FABRICATED REPAIR PLIES USING BMS 8-79 ST 120 LOT#1476039-1; AND BMS 5-129 GR5 LOT#1469320-2; STARTED INSTALLING REPAIR PLIES IAW SRM 51-70-05-2R-1 PAR 4C.; [05] COMPLETED INSTALLATION OF REPAIR PLIES; VACUUM BAGGED; LEAK CHECK GOOD; CURED AND UNBAGGED IAW SRM 51-70-05-2R-1 PARA 4C-E.<BR>USED HEATCON BONDER ID:ATS532 S/N:15092117<BR>AND HEATCON BONDER ID:NCX000523 S/N:11051262; [06] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 4 AND 5. POST REPAIR UT INSPECTED PER 737NDT PART 4 51-00-02. NO DEFECTS FOUND. TOOL E650 ATS2341.; [07] REFINISHED REPAIR AREAS IAW SRM 51-70-05-2R-1 PAR 4G AND AMM 51-21-99-300-802 PAR 3C(1).<BR><BR>COMPLETED SRM REPAIR 51-70-05-2R-1.; [08] FINAL INSPECTION. JOB COMPLETE PER SRM 51-70-05-2R-1.