What was found
CRACK FOUND IN RT AC BAY UPPER ATTACH ANGLE AT BS 663 RBL 8. CRACK VERIFIED WITH HFEC. CUT & REMOVED ATTACH ANGLE IAW SRM 57-10-10-2R-5 FIG 202 SHEET 4; PERFORMED DVI OF REPAIR AREA & UNDERLYING STRUCTURE. NO DEFECTS NOTED IAW SRM 57-10-10-2R-5 REPAIR 5; FABRICATED REPAIR PARTS IAW SRM 57-10-10-2R-5 REPAIR 5. TREATED & PRIMED REPAIR PARTS & CUT EDGE IAW SRM 57-10-10-2R-5 REPAIR 5; INSTALLED IAW SRM 57-10-10-2R-5 REPAIR 5. APPLIED FILET SEAL & CAP SEAL TO REPAIR & REPAIR FASTENERS IAW SRM 57-10-10-2R-5 & AMM 51-31-00-390-805. CAP SEAL EXTERIOR AREA ONLY.; APPLIED CIC TO REPAIR AREA IAW SRM 57-10-10-2R-5 STEP O. CAP SEALED TANK FASTENERS INTERNALLY IAW SRM 57-10-10-2R-5 & AMM 51-31-00-390-805.