What was found
IN THE FWD CARGO AREA; THE ENTRY THRESHOLD UPPER SURFACE HAS NUMEROUS AREAS OF CORROSION FROM STATION 440 TO 492. ; / [01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .012?. DAMAGE FOUND TO BE BEYOND ALLOWABLE LIMITS AS GIVEN IN SRM 53-00-53-1A-2.; [02] REMOVED FORWARD CARGO THRESHOLD WEB I.A.W SRM 51-40-02 FOR REPLACEMENT.; [03] LOCATED AND DRILLED HOLES IN NEW WEB PER SRM 51-40-05.INSTALLED NUTPLATES PER SRM 51-40-02.; [04] OK TO INSTALL THRESHOLD; [05] INSTALLED NEW WEB PER SRM 51-40-02.; [06] INSPECTED WORK PERFORMED ON C/A #5; [07] CERTIFY; [08] REMOVED AND REPLACED FWD CARGO ENTRY WEB REF STEPS 1 THRU 6.