What was found
SUPPLEMENTAL INFORMATION: CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 RBL12 TO RBL17. ; / [01] CORROSION ON BULKHEAD SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.; [02] VERIFIED CORRECTIVE ACTION ITEM 1.; [03] REMOVED BULKHEAD FLOOR SUPPORT ANGLE BS947 RBL12 TO RBL17 PER SRM 51-40-02-0G-0; [04] LOCATED AND DRILLED NEW FLOOR SUPPORT ANGLE BS 947 RBL12 TO RBL17 IAW SRM 51-40-05-0G-0 AND DWG 147A7500; DWG 149A8117; [05] VERIFIED CORRECTIVE ACTION 4.; [06] OK TO INSTALL BULKHEAD ANGLE; [07] OKAY TO INSTALL BULKHEAD ANGLE AT BS 947 RBL 12 TO RBL 17.; [08] INSTALLED BULKHEAD SUPPORT ANGLE PER SRM 51-40-02-0G-0 AND DWG 147A7500; [09] INSTALLED BULKHEAD SUPPORT ANGLE PER SRM 51-40-02-0G-0 AND DWG 147A7500 AND DWG 149A8117; [10] VERIFIED CORRECTIVE ACTION 9.