What was found
SUPPLEMENTAL INFORMATION: FWD CARGO BAY BULKHEAD GUSSET IS CRACKED AT BS 500D COMMON TO STR19R ; / [01] REMOVED; LOCATED AND DRILL NEW FWD CARGO BAY BULKHEAD GUSSET AT BS 500D; STR 19RIAW SRM 51-40-02-0G-0;SRM 51-40-05-0G AND DWG 143A7902;ID: 174; REV:-; [02] REMOVED; LOCATED AND DRILL NEW FWD CARGO BAY BULKHEAD GUSSET AT BS 500D; STR 19R IAW SRM 51-40-02-0G-0;SRM 51-40-05-0G AND DWG 143A7902;ID: 174; REV:- ; OK TO INSTALL; [03] CERTIFIED STEP 1 AND 2; [04] VERIFIED CORRECTIVE ACTION 2.<BR>OK TO INSTALL; [05] INSTALLED NEW FWD CARGO BAY BULKHEAD GUSSET AT BS 500D; STR 19R IAW SRM 51-40-02-0G-0 AND DWG 143A7902;ID: 174; REV:-; [06] CERTIFIED STEP 5 COMPLETE; [07] VERIFIED INSTALLED NEW FWD CARGO BAY BULKHEAD GUSSET AT BS 500D; STR 19R IAW SRM 51-40-02-0G-0 AND DWG 143A7902;ID: 174; REV:-