What was found
SUPPLEMENTAL INFORMATION: DEFORMED INTERCOSTAL AT FWD CARGO BAY BS 500D+10 RBL 6. ; / [01] RECEIVED NEW INTERCOSTAL FROM OUT CUSTOMER SERVICE HEAT TREAT CUSTOMER CARD RO # 851436-SWA; [02] REMOVED ; LOCATED AND DRILLED NEW INTERCOSTAL AT FWD CARGO BAY BS 500D + 10; LBL 6 ;WL 158 IAW SRM 51-40-02-0G-0;SRM 51-40-05-0G-0 AND DWG 143A7902; ID: 126; REV: A; APPLIED CHEMICAL CONVERSION IAW AMM 51-21-41-370-802; OK TO APPLY PRIMER; [03] VERIFIED STEPS 1 AND 2 COMPLETE; [04] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS; [05] INTERCOSTAL FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2; STEP 4C; [06] VALIDATED STEPS 4 AND 5; [07] VERIFIED CORRECTIVE ACTIONS 2-6.<BR>OK TO PRIME; [08] APPLIED PRIMER ON NEW INTERCOSTAL AT FWD CARGO BAY BS 500D + 10; LBL 6 ;WL 158 IAW AMM 51-21-72-370-804; OK TO INSTALL; [09] APPLIED PRIMER ON NEW INTERCOSTAL AT FWD CARGO BAY BS 500D TO BS 520; LBL 6 ;WL 158 IAW AMM 51-21-72-370-804; OK TO INSTALL NEW INTERCOSTAL AT FWD CARGO BAY BS 500D TO BS 520; [10] OKAY TO INSTALL NEW INTERCOSTAL AT BS 500D TO BS 520 LBL6 WL 158.; [11] INSTALLED NEW INTERCOSTAL AT FWD CARGO BAY BS 500D AND BS 520; RBL 6 ;WL 158 IAW SRM 5140-02-0G-0 AND DWG 143A7902; ID: 126; REV: A; [12] INSTALLED NEW INTERCOSTAL AT FWD CARGO BAY BS 500D AND BS 520; RBL 6 ;WL 158 IAW SRM 5140-02-0G-0 AND DWG 143A7902; ID: 126; REV: A; [13] VERIFIED CORRECTIVE ACTIONS STEP 11.; [14] VERIFIED JOB COMPLETE