What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL AT RBL 21 BS 867; BS 867+15; BS 927+4; BS 927+12. ; / [01] EVALUATED CORROSION; THE CORROSION AT BS 867 AND BS 867+15 ARE EVALUATED ON CUST CARD#TTG8Q00A5VCW; FOUND DEEPEST AREA TO BE AT BS 927+12 RBL 21 WL 178; FOUND 0.015 REMOVED FROM ORIG 0.040 IN 1'X1' AREAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2677; [02] VERIFIED CORRECTIVE ACTION ITEM 1.; [03] RECEIVED NEW ACB FLOOR TO SIDEWALL SUPPORT <BR><BR>ITEM : 146A7502-56<BR>PO# : 845703/2; [04] REMOVED ACB FLOOR TO SIDEWALL SUPPORT BS 867 - 887 RBL21 IAW SRM 51-40-02-0G-0; [05] LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0 AND DWG 146A7502 REV : -; [06] RECEIVED NEW ACB FLOOR TO SIDEWALL SUPPORT <BR><BR>ITEM : 147A7501U17<BR>PO# : 842226/1; [07] REMOVED ACB FLOOR TO SIDEWALL SUPPORT BS 867 - 947.5 RBL21 IAW SRM 51-40-02-0G-0; [08] LOCATED; DRILLED AND COUNTERSANK NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0; SRM 51-40-08-0G-0 AND DWG 147A7501 REV:A; [09] EDITED CORRECTIVE ACTION STEP 3;4;5 TO STEP 6;7;8; [10] VERIFIED CORRECTIVE ACTION #8; [11] OK TO INSTALL; [12] VERIFIED OK TO INSTALL; [13] INSTALLED ACB NEW FLOOR TO SIDEWALL SUPPORT AT RBL21 BS 867 - 947.5 IAW SRM 51-40-02-0G-0; DWG 147A7500 REV:-; DWG 147A9409 REV:-; AND DWG 147A0060 REV:-; [14] VERIFIED CORRECTIVE ACTION #13; [15] VERIFIED ALL STEPS COMPLETE